ELECTRODES

Aquaprobes are supplied with a standard set of parameters and customisable ports to take Ion Selective Electrode (ISE) and optical electrodes.


Applications

  • For use with Aquaprobes



Key features

  • Small diameter optical and ISE electrodes.


PRODUCT SPECIFICATIONS

Note: Due to constant development, specifications may change without prior notice.

Please click the Want To Know More? link next of each parameter for extra details on the sensor and why it is used in water monitoring.

Standard Parameters

Optical Dissolved Oxygen

Want To Know More?

Range

0 – 500.0% / 0 – 50.00 mg/L

Resolution

0.1% / 0.01mg/L

Accuracy

0 - 200%: ± 1% of reading. 200% - 500%: ± 10%

Conductivity (EC)

Want To Know More?

Range

0 – 200 mS/cm (0 - 200,000 µS/cm)

Resolution

3 Auto-range scales: 0 – 9999 µS/cm, 10.00 – 99.99 mS/cm, 100.0 – 200.0mS/cm

Accuracy

± 1% of reading or ± 1µS/cm if greater

TDS*

Want To Know More?

Range

0 – 100,000 mg/L (ppm)

Resolution

2 Auto-range scales: 0 – 9999mg/L, 10.00 – 100.00g/L

Accuracy

± 1% of reading or ± 1mg/L if greater

Resistivity*

Want To Know More?

Range

5 Ωcm – 1 MΩcm

Resolution

2 Auto-range scales: 5 – 9999 Ωcm, 10.0 – 1000.0 KΩcm

Accuracy

± 1% of reading or ± 1 Ωcm if greater

Salinity*

Want To Know More?

Range

0 – 70 PSU / 0 – 70.00 ppt (g/Kg)

Resolution

0.01 PSU / 0.01 ppt

Accuracy

± 1% of reading or ± 0.1 unit if greater

Seawater Specific Gravity*

Range

0 – 50 st

Resolution

0.1 st

Accuracy

± 1.0 st

pH

Want To Know More?

Range

0 – 14 pH / ± 625mV

Resolution

0.01 pH / ± 0.1mV

Accuracy

± 0.01 pH / ± 5mV

ORP

Want To Know More?

Range

± 2000mV

Resolution

0.1mV

Accuracy

± 5mV

Temperature

Range

-5°C – +50°C (23°F – 122°F)

Resolution

0.1° C/F

Accuracy

± 0.5° C

* Readings calculated from EC and temperature values


Optional Parameters

Depth **

Range

00 – 100m (0 – 330F)

Resolution

0.01m/F

Accuracy

± 1%

**Option on the AP-2000. Comes as standard on the AP-5000 and AP-7000


Ion Specific Electrodes***

Ammonium

Want To Know More?

Range

0 – 1,000mg/L (ppm)

Resolution

2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 – 999.9 mg/L

Accuracy

± 10% of reading

Ammonia†

Want To Know More?

Range

0 – 1,000mg/L (ppm)

Resolution

2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 – 999.9 mg/L

Accuracy

± 10% of reading

Chloride

Range

0 – 1,000mg/L (ppm)

Resolution

2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 – 999.9 mg/L

Accuracy

± 10% of reading

Flouride

Range

0 – 1,000mg/L (ppm)

Resolution

22 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 – 999.9 mg/L

Accuracy

± 10% of reading

Nitrate

Range

0 – 1,000mg/L (ppm)

Resolution

2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 – 999.9 mg/L

Accuracy

± 10% of reading

Calcium

Range

0 – 1,000mg/L (ppm)

Resolution

2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 – 999.9 mg/L

Accuracy

± 10% of reading

† Ammonium electrode required. Readings calculated from Ammonium, pH and temperature electrode values.


Optical Electrodes***

Turbidity

Want To Know More?

Range

00 – 3000 NTU

Resolution

2 Auto-range scales: 0.0 99.9 NTU, 100 – 3000 NTU

Repeatability

± 2% of reading

Chlorophyll

Range

0 – 500 µg/L (ppb)

Resolution

0.1 µg/L

Repeatability

± 2% of reading

Phycocyanin (Freshwater Blue-Green Algae)

Range

0 – 300,000 cells/mL

Resolution

1 cell/mL

Repeatability

± 2% of reading

Phycoerythrin (Marine Blue-Green Algae)

Range

0 – 200,000 cells/mL

Resolution

1 cell/mL

Repeatability

± 2% of reading

Rhodamine WT Dye

Range

0 – 500 µg/L (ppb)

Resolution

0.1 µg/L

Repeatability

± 5% of reading

Fluorescein Dye

Range

0 – 500 µg/L (ppb)

Resolution

0.1 µg/L

Repeatability

± 5% of reading

Refined Oil

Range

0 – 10,000 µg/L (ppb)

Resolution

0.1 µg/L

Repeatability

± 2% of reading

 


***Note

1.

In addition to the standard parameters supplied with the base Aquaprobe, the AP-2000 has 1 ISE port and 1 optical port, the AP-5000 has 4 ports that can take any combination of ISE or optical sensors and the AP-7000 has 6 ports that can also take any combination of ISE or optical sensors.

2.

The accuracy figures quoted above represent the equipment's capability at the calibration points at 25°C. These figures do not take into account errors introduced by variations in the accuracy of calibration solutions and errors beyond the control of the manufacturer that may be introduced by environmental conditions in the field.

 


 
Back to content | Back to main menu